These refurbished Waters AllianceHT 2790 and 2795 HPLC systems comes with Waters 2996 PDA Detector.
We have other Waters HPLC detectors as options
- Waters 996 Photodiode Array Detector
- Waters 2996 PDA Detector
- Waters 2998 PDA Detector
- Waters 2487 Dual wavelength Detector
- Waters 474 Scanning Fluorescence Detector
- Waters 2475 Fluorescence Detector
- Waters 410 Refractive Index Detector
- Waters 2410 RID
- Waters 2414 RID
This refurbished Waters Alliance 2790 HPLC system is in great condition. It has been tested at SpectraLab Scientific. A 90 day warranty is included.
We are seasoned professionals in this area and we would be happy to have you speak with one of our experts here at SpectraLab.
Thanks for looking and we look forward to hearing from you!
Solvent Management | ||
---|---|---|
Number of Solvents: | One to four, three with vacuum degas | |
Solvent Conditioning | Vacuum degas, three solvents plus purge solvent | |
Typical Operating Flow Rate Range | 0.050 to 5.000 mL/min in 0.001-mL/min increments | |
Programmable Flow Rate Range | 0.000 and 0.010 to 10.000 mL/min in 0.001-mL/min increments | |
Compressibility Compensation | Automatic and continuous | |
System Delay Volume | <400 µL, independent of backpressure, 1 mL/min | |
Plunger Seal Wash | Integral, active, programmable | |
Gradient Profiles | Eleven (11) gradient curves [including linear, step (2 curves), concave (4 curves), and convex (4 curves)] | |
Dry Prime/Wet Prime | Automatic, front panel control | |
Flow Ramping | Time (0.01 to 30.00 min in 0.01-min increments) to reach maximum flow rate) to reach maximum flow rate | |
Maximum Operating Pressure Maximum Operating Pressure: | 5000 psi (345 bar) at 0.010 to 3.000 mL/min; Programmable upper and lower limits | |
Composition Range: | 0.0 to 100.0% in 0.1% increments | |
Composition Accuracy | ±0.5% absolute, independent of backpressure] (Proportioning Valve Pair Test [degassed methanol: methanol/propylparaben, 2 mL/min, 257 nm]) | |
A Composition Precision | <=0.15% RSD or<=0.02 min SD, whichever is greater, based on retention time. (Degassed 60% methanol:40% water Dial-a-Mix, 1 mL/min, six replicates, phenone mix, 257 nm) | |
Flow Precision | <=0.075% RSD or <=0.02 min SD, whichever is greater, based on retention time (N = 6) or volumetric measures (0.200 to 5.000 mL/min), isocratic premix | |
Flow Accuracy | <=1% or 10 µL/min, whichever is greater, (0.200 to 5.000 mL/ min), degassed methanol, at 600 psi backpressure |
Sample Management | ||
---|---|---|
Number of Sample Plates | Total of four plates: – Microtiter plate – 96- or 384-well – Vial plate – 2.0-mL vial (48) – Tube plate – 0.5-mL micro-centrifuge tube (48) or 1.5-mL micro-centrifuge tube (24) – Open access plate – 2.0-mL vial (24 or 48) |
|
Sample Temperature Control | 4 to 40° C, programmable in 1° C increments | |
Maximum Sample Capacity | 1536 in four 384-well plates | |
Number of Sample Injections | 1 to 99 injections per sample | |
Sample Delivery Precision | <0.3% RSD, full loop 50 µL. (Default wash/purge conditions, degassed 60% methanol: 40% water Dial-a-Mix, 1 mL/min, six replicates, paraben mix, 257 nm) | |
Sample Volume Linearity | >0.999% correlation, 5 to 20 µL, partial fill in 50-µL loop, 3-µL pre- and post-sample air gaps (Default wash/purge conditions, degassed 60% methanol:40% water Dial-a-Mix, 1 mL/min, six replicates, paraben mix, 257 nm) | |
Needle Wash Solvents | Two: wash (strong solvent) and purge (sample- compatible) solvent A | |
Sample Carryover | <0.01% or <2.5 nL (default wash/purge volumes), whichever is greater. (Blank injection, 25 µL, 60% methanol:40% water, after six replicates, 25 µL propylparaben, 1 g/L, 257 nm) |