The CE440 Elemental Analyzer by Exeter Analytical Inc. uses a thermal conductivity detection method to measure carbon, hydrogen, and nitrogen after combustion and reduction. This method gives rapid and highly accurate measurements over a very wide range of elemental compositions, with most measurements completed in less than 5 minutes.
Accuracy and Precision – The CE440 provides analytical data of unsurpassed accuracy and precision. The complete control of combustion parameters combined with steady state measurement of combustion products ensures a level of accuracy and precision that cannot be matched. Sample Data.
Versatility – With its unique combination of both static and dynamic combustion, the CE 440 can combust the widest range of sample types of any CHN/O/S instrument. Our unique horizontal furnace allows for automatic removal of the residue from each sample after analysis, avoiding memory effects and gas flow problems, which can occur with vertical furnace systems.
Reliability – The CE440 is a fully automated CHN/O/S elemental analyzer. The system with its Window® based P.C. operating software has been designed to reduce human error through incorporation of extensive automation, customer help, and diagnostic facilities. Using the technique of steady-state measurement of combustion products, the CE440 is inherently more reliable than gas chromatographic systems which are dependent on flow, column temperature, and dead volume management.
Low gas and reagent consumption combined with higher reduction tube life make it the most economical CHN/O/S elemental analyzer to operate.
Continuous diagnostics and automatic maintenance alerts make operation almost fool-proof. By monitoring signals, voltages, and sample throughput, the instrument provides you with continuous status reports on consumable reagents as well as an immediate warning should a problem occur. And, most parts are user-replaceable, further reducing cost and downtime.
Specifications
Type | Specifications |
---|---|
Accuracy | With standard organic compounds: +/-0.15% absolute plus +/- 0.15% relative |
Sample Size | Typically 1-5mg, up to 500mg for samples with low carbon content |
Analysis Time | Less than 5 minutes for CHN |
Automation | 64 sample carousel or single sample with ability to re-weigh for ash |
Range | 100 ppm to 100% |
Detector | Thermal Conductivity |
System Sensitivity | +/0 1 microvolt |
Analytical Sensitivity | Less than 1 microgram |
Dimensions (w x d x h) | 81 x 71 x 33cm |
Bottled Gases Required | Helium 99.99%, Oxygen 99.99% |