This HP / Agilent 1200 Series HPLC system comes with the following:
- Solvent Tray
- Agilent 1200 Series G1379B Degasser
- Agilent 1200 Series G1312A Bin Pump
- Agilent 1200 G1367B HiP ALS Autosampler
- Agilent 1200 G1330B FC/ALSTherm
- Agilent 1200 Series G1316A TCC
- Agilent 1200 Series G1315B DAD
- PC with Suitable software and all essential cables required for full operation
Agilent 1200 series G1379B Degasser
Type | Specification |
Maximum flow rate | 0 – 5 ml/min per channel |
Number of channels | 4 |
Internal volume per channel | Typically 1 ml per channel |
Materials in contact with solvent | PTFE, FEP,PEEK |
pH range | 1 – 14 |
RS-232 output | For diagnostic purposes |
Agilent 1200 Series G1312A Bin pump
Type | Specification |
Hydraulic system | Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve |
Setable flow range | Setpoints 0.001 – 5 ml/min, in 0.001 ml/min increments |
Flow range | 0.1 – 5.0 ml/min |
Flow precision | <0.07% RSD, or <0.02 min SD whatever is greater, based on retention time at constant room temperature |
Flow accuracy | +1% of 10µl/min whatever is greater |
Pressure | Operating range 0 400 bar (0-5880 psi) up to 5 ml/min |
Pressure pulsation | < 2% amplitude (typically < 1%), at 1 ml/min isopropanol, at all pressures > 1 MPa |
Compressibility compensation | User-selectable, based on mobile phase compressibility |
Recommended pH range | 1.0 – 12.5, solvents with pH <2.3 should not contain acids which attack stainless steel |
Gradient formation | High-pressure binary mixing, delay volume 180-480 µl without mixer, 600 – 900 µl with mixer, dependent on back pressure |
Composition range | 1 – 99 % or 5 µl/min per channel, whatever is greater |
Composition precision | <0.5% absolute |
Composition accuracy | 0.15% RSD, at 1 ml/min |
Control and data evaluation | Agilent ChemStation for LC |
Analog output | For pressure monitoring, 2mV/bar, one output |
Communications | Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional |
Safety and maintenance | Extensive diagnostics, error detection and display (through handheld controllers G4208A, G1323B and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltage in major maintenance areas |
GLP features | Early maintenance feedback (EMF) for continuous tracking of instruments usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors. |
Housing | All materials recyclable |
Agilent 1200 G1367B HiP ALS Autosampler
Type | Specification |
GLP features | Early maintenance feedback (EMF), electronic records of maintenance and errors |
Communications | Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output |
Safety features | Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display |
Injection range | 0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required) |
Precision | Typically < 0.25% RSD from 5 – 100 µl, Typically < 1% RSD from 1 – 5 µl variable volume |
Pressure range | 400 bar (5880 psi) |
Sample viscosity range | 0.2 – 5 cp |
Sample capacity | 2 × well plates (MTP) + 10 × 2 ml vials 108 x 2-mL vials in2 x 54 vial plate plus 10 additional 2 mL vials 30 x 6-mL vials in 2 x 15 vial plate plus 10 additional 2 mL vials54 Eppendorf tubes (0.5/1.5/2.0mL) in 2 x 27 Eppendorf tube plate Also compatible with the Agilent 1200 Series sample capacity extension for further expansion of the sample capacity |
Injection cycle time | Typically < 30 s using following standard conditions: Default draw speed: 200 µl/min Default eject speed: 200 µl/min Injection volume: 5 µl |
Carry-over | Typically < 0.01% using the following conditions: Column: 125 x 4 mm Hypersil ODS, 5 µm Mobile phase: Water/Acetonitrile = 80/20 Flow rate: 1 ml/min Injection volume: 1 µl caffeine (1 mg/ml), 5 µl water to test carryover Outside wash of needle before injection: 20 sec with water using flush port |
Agilent 1200 series G1316A TCC
Type | Specification |
Temperature range | 10 degrees below ambient to 80 °C up to 80 °C: flow rates up to 5 ml/min |
Temperature stability | ± 0.15 °C |
Temperature accuracy | ± 0.8 °C ± 0.5 °C (with calibration) |
Column capacity | Three 30 cm |
Warm-up/cool-down time | 5 minutes from ambient to 40 °C 10 minutes from 40 – 20 °C |
Dead volume | 3 µl left heat exchanger 6 µl right heat exchanger |
Communications | Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series module |
Safety and maintenance | Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP features | Column-identification module for GLP documentation of column type |
Housing | All materials recyclable |
Aglient 1200 series G1315B DAD
Wavelength range | 190-950 nm |
Light source | Deuterium and tungsten lamps |
Detection type | 1024 – element photodiode array |
Short term noise (ASTM) single & mult-wavelength | ± 1° x 10-5 AU at 254 and 750 nm |
Drift | 2° x 10-3 AU / hr at 254 nm |
Linear absorbance range | > 2 AU (upper limit) |
Wavelength accuracy | ± 1 nm |
Wavelength bunching | 1 – 400 nm |
Diode width | < 1 nm |
Flow cells | Standard: 13µl volume 10 mm cell path length and 120 bar (1760 psi) pressure maximum Semi-Micro: 5µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum Micro: 2µl volume, 3 mm cell path length and 120 bar (1760 psi) pressure maximum High Pressure: 1.7µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure max. 80 nano: 0.08µl volume, 100 mm cell path length and 50 bar (725 psi) pressure max. 500 nano: 0.5µl volume, 10 mm cell path length and 50 bar (725 psi) pressure max. |
Analog outputs | Recorder / integrator: 10 mV or 1 V, output range 0.001 – 2 AU, two outputs |
Control and data evaluation | Agilent Chemstation for LC |
Slit width | 1, 2, 4, 8, 16 nm |
Communication types | CAN, GBIP, RS-232C, APG, Remote: ready, start, stop and shut down |
Wavelength range | 190-950 nm |
Light source | Deuterium and tungsten lamps |
Detection type | 1024 – element photodiode array |
Short term noise (ASTM) single & mult-wavelength | ± 1° x 10-5 AU at 254 and 750 nm |
Drift | 2° x 10-3 AU / hr at 254 nm |
Linear absorbance range | > 2 AU (upper limit) |
Please feel free to contact our professional team members if you have any concern.
Your satisfaction is our first priority and we do appreciate your preference and look forward to serving you in the near future.