Solvent Conditioning | Vacuum degas,two (2) operating modes, four (4) chambers, < 500 µL internal volume per chamber |
Programmable Flow Rate Range | 0.000 and 0.010 to 10.000 mL/min. in 0.001 mL/min. increments |
Effective System Delay Volume | < 650 µL , independent of backpressure @ 1 mL/min. |
Plunger Seal Wash | Integral, active, programmable |
Gradient Profiles | Eleven (11) gradient curves (including linear, step [2], concave [4], and convex [4]) |
Maximum Operating Pressure | 5000 psi. (345 bar) (0.010 – 3.000 mL/min) Programmable upper and lower limits |
Pressure Ripple | <2.5% (1 mL/min., degassed methanol, at 1700 psi backpressure) |
Composition Range | 0.0 to 100.0%, in 0.1% increments |
Composition Accuracy | ±0.5% absolute, independent of backpressure (Proportioning Valve PairTest, [degassed methanol: methanol/propylparaben, 2 mL/min., 254 nm]) |
Composition Precision | 0.15%RSD or 0.02 min. SD, whichever is greater, based on retention time.(Degassed methanol:water, 60:40 dial-a-mix, 1 mL/min., 6 replicates,phenone mix, 254 nm) |
Flow Precision | 0.075%RSDor 0.02 min. SD, 6 replicates, based on retention time or volumetric measures (0.200 – 5.000 mL/min.), isocratic premix |
Flow Accuracy | ± 1% or 10 µL/min. whichever is greater, (0.200 – 5.000 mL/min.), (Degassed methanol, at 600 psi backpressure) |
Sample Management
Number of Sample Vials |
120 vials, configured in 5 carouselsof 24 vials each |
Number of Sample Injections |
1 to 99 injections per sample vial |
Sample Delivery Precision |
Typically < 0.5% RSD, 5 – 80 µL (Degassed methanol: water, 60:40 dial-a-mix, 1 mL/min., 6 replicates, phenone mix, 254 nm) |
Sample Carryover |
< 0.1% |
Injection Accuracy |
± 1µL (± 2%) (50 µL, N=6), Sample: 100% degassed water, Analytical solvent: 100% degassed methanol |
Sample Temperature Control |
4 to 40°C, programmable in 1°C increments |
Advanced Operations |
Stat runs, Auto additions, Auto standards |
Injection Volume Range |
0.1 to 100 µL, standard; 0.1 to 2000 µL, with optional sample loop |
Injector Linearity |
> 0.999 coefficient of deviation (1 to 100 µL) |
Waters 2410 Refractive index detector (RID)
Conditions | Specifications |
RI Range | 1.00 to 1.75 RIU |
Measurement Range | 5 × 10–3 RIU maximum FS (SENS = 1, SF = 1) 5 × 10–8 RIU minimum FS (SENS = 1024, SF = 100) |
Flow Rate | 0.03 to 10 mL/min |
Noise (after one-hour warm-up) |
≤ 2.0 × 10–8 RIU, (TC = 1, SF = 80, SENS = 64, THF at 24 °C with restrictor coil) |
Drift | 2.5 × 10–7 RIU/hr (static with THF) TC = 1, SF = 20, SENS = 32 |
Sensitivity Settings |
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024 |
Time Constant Filter Settings |
0.2, 1, 3, 10 seconds |
Analog Outputs | –2.0 V to +2.0 V |
Temperature Control | Internal oven: 30 to 50 °C (86 to 122 °F) External column heaters: • Ambient to 150 °C (302 °F), steel • Ambient to 80 °C (176 °F), plastic |
Light Source | Light emitting diode (LED) |
Flow Cell | Fused quartz |
Cell Volume | 10 µL |
Pressure Limit | 100 psi |
Fluidic Path Materials |
316 stainless steel, Dynasil®, Suprasil II®, PTFE, Kalrez®, quartz |