Specifications
Dimensions and Weights
-Size: 53 cm (h) x 66 cm (w) x 56 cm (d)
– Weight: 43 kg
Environmental Conditions
-Operating temperatures: 10°C to 40°C
-Operating humidity (relative): 5% to 95%
-Line voltage requirements: 101V, 120V, 230V (±10% nominal)
Column Oven
-Dimensions: 28 cm (w) x 20 cm (d) x 28 cm (h)
-Temperature range: ambient +4 °C to 450 °C
-With liquid N2: -99 °C to 450 °C
-With liquid CO2: -65 °C to 450 °C
-Temperature program ramps/holds: 7/8
-Maximum temperature ramp rate: 100 °C/min for all voltages
-Cool down rate: 400 °C to 50 °C in 4.5minutes
-Temperature set-point resolution: 1 °C
Injector Options
-Maximum injectors: three operating concurrently
-Pneumatics: manual or electronic flow control (EFC)
-Columns: capillary columns standard with optional packed column adapter
-Injectors
-CP-1177Split/Splitless
-1079 Programmable Temperature Vaporizing (PTV)
-1061 Flash Megabore/Packed
-1041 On-Column Megabore/Packed
CP-1177 Split/Splitless
-Pressure range: 0-100 psi
-Total flow: 500 rrillrnin at 10 psi
-Maximum temperature: 450 °C
-Split range: 1-10,000 (column dependent)
1079 Programmable Temperature Vaporizing (PTV)
-Pressure range: 0-100 psi
-Total flow: 500 mL/min at 10 psi
-Temperature range
– -99 °C to 450°C liquid N2
– -65 °C to 450°C liquid CO2
-Maximum temperature ramp rate: 180 °C/min
-Temperature ramps: 4
-Split range: 1-10,000 (column dependent)
– Operational modes
– Temperature ramped splitless
– Coldon-column
– Large Volurne Injection
– Split and splitless
– ChromatoProbe solid sample introduction:
optional
1061 Flash Megabore/Packed
-Pressure range: 0-100 psi
-Total Flow: 50 mL/min (Type 3 EFC)
500mL/min (Type 4 EFC)
-Maximum temperature: 450 °C
1041 On-Column Megabore/Packed
-Pressure range: 0-100 psi
-Total Flow: 50 mL/min (Type 3 EFC)
500mL/min (Type 4 EFC)
-Maximum temperature: 450 °C
FID
-Maximum temperature: 450 °C
-Detectivity: 2 pg C/see
-Linear dynamic range: 107
-Patented ceramic -Flame tip: standard
-Flame-out detection/auto re-ignition: standard
TCD
-Maximum temperature: 450 °C
-Detectivity: 300 pg/sec (C4)
-Linear dynarnic range: 106
-Filament proteefirm: standard
-Automatic bridge balancing: standard
ECD
-Maximum temperature: 450 °C
-Detectivity: 7 fg/sec Lindane
-Linear dynamic range: 104
This refurbished Varian 3800 GC comes with FID, ECD, TCD and also NCT (Methanizer).
It\’s in great condition, and has been tested at SpectraLab Scientific.
A 90 day warranty is included.
Please feel free to contact our professional team members if you have any concerns.
Your satisfaction is our first priority and we do appreciate your inquiries, and look forward to serving you in the near future.