Features:
- Modular design allows versatility in configuring a wide variety of applications
- performance improvements up to an order of magnitude in flow rate accuracy
- electronics stability and conductivity cell temperature control increase retention time reproducibility, baseline stability, and sensitivity
- New hydroxide and carbonate Reagent-Free Ion chromatography consumables offer the greatest flexibility of any RFIC system
- Dual-system capability (within the same foot print) maximizes throughput
- Integrated DC Detector/chromatography module with precisely controlled temperature zones maintains baseline stability and increases application flexibility
- AM Automation Manager simplifies and automates complex applications including sample preparation, preconcentration, matrix elimination and post column reagent addition
- New innovative ED Electrochemical Detector capabilities improve and expand application:multi-waveforms in a single run; post-run 3-D data processing: new cell design
- Innovative touchscreen Tablet Station, mounted on a movable arm, unifies and simplifies system control and operation
This Dionex ICS 3000 Ion Chromatography System includes:
- Single or Dual Pump (DP/ SP)
- Eluent Generator (EG)
- Eulent Organizer
- Detector/Chromatography Module (DC)
- AS Autosampler
This is a sample set. We have many more components, so please feel free to contact us if you have any requests. A 90 day warranty is included.
We look forward to hearing from you in the future.
Specifications:
Feature | Isocratic Pump | Gradient Pump |
Pump |
Dual-piston (in series), variable speed, 80 μL per revolution |
Dual-piston (in series), variable speed, 80 μL per revolution |
Flow Rate Range |
0.001 to 10.0 mL/min in increments of 0.001 mL/min |
0.001 to 10.0 mL/min in increments of 0.001 mL/min |
Flow Rate Accuracy and Reproducibility |
±0.1% at 1.0 mL/min (typical) |
±0.1% at 1.0 mL/min (typical) |
Operating Pressure | 0.1 to 35 MPa (15 to 5000 psi) | 0.1 to 35 MPa (15 to 5000 psi) |
Pressure Ripple | 1% (typical) | 1% (typical) |
Gradient Proportioning Accuracy and Reproducibility | Not applicable |
±0.5% at 2.0 mL/min (typical) |
Number of Eluents | One | Four |
Gradient Mixer Delay Volume | Not applicable |
GM-3: <500 μL, 3 to 9 mm ID columns GM-4: <290 μL, 2 mm ID columns |
High Pressure Limit |
0 to 35 MPa (0 to 5000 psi) in increments of 0.1 MPa (14 psi); trips instantaneously |
0 to 35 MPa (0 to 5000 psi) in increments of 0.1 MPa (14 psi); trips instantaneously |
Low Pressure Limit |
0 to 34 MPa (0 to 4900 psi) in increments of 0.1 MPa (14 psi) |
0 to 34 MPa (0 to 4900 psi) in increments of 0.1 MPa (14 psi) |
Vacuum Degassing Module |
Built-in single-channel degas chamber (with degassing membrances) with internal volume of 670 µL and dual-stage diaphragm vacuum pump |
Built-in four-channel degas chamber (with degassing membranes) with internal volume of 670 μL per channel and dual-stage diaphragm vacuum pump |
Eluent Generator | |
Operating Temperature |
4 to 40 °C (40 to 104 °F) |
Operating Humidity |
5% to 95% relative humidity, noncondensing |
Operating Pressure |
Minimum: 14 MPa (2000 psi) Maximum: 21 MPa (3000 psi) |
Dimensions |
Height: 40.6 cm (16 in) Width: 22 cm (8.75 in) Depth: 55.9 cm (22 in) Minimum required clearance behind the EG: 5 cm (2 in) |
Weight | 18 kg (40 lb) |
Conductivity Detector | |
Electronics | Microprocessor-controlled digital signal processing |
Detection Types | Single- or dual-conductivity detection. Dual-detection can be controlled either simultaneously or independently |
Cell Drive | 8 kHz square wave |
Linearity | 1% at 1000 µS |
Resolution | 0.10 nS |
Signal Sampling Rate | Maximum of 100 Hz |
Electronic Noise, Dry | S/N ratio = 200,000:1 (Example: 1000 µS:5 nS) |
Electronic Noise, Wet |
At 23 µS, noise <0.2 nS At 1 µS, noise <0.1 nS |
Filter | Rise times from 0 to 10 s |
Temperature Compensation | Factory set at 1.7% per °C; programmable from 0.0 to 3.0% per °C |
Cell Body | PEEK |
Cell Electrodes | Passivated 316 stainless steel |
Active Volume of Cell | < 1.0 µL |
Cell Operating Temperature | 5 ºC above the DC detector compartment temperature; maximum of 60 ºC |
Cell Maximum Operating Pressure | 3 MPa (500 psi) |
Signal Gain Ranges | 0 to 180 µS, 0 to 1000 µS, and 0 to 15,000 µS |
Optional Analog Output Full-Scale Ranges | Three separate ranges from 0 to 15,000 µS |
Electrochemical Detector | |
Electronics | Microprocessor-controlled digital signal processing |
Detection Types | Single- or dual-electrochemical detection. Dual-detection can be controlled either simultaneously or independently. |
Noise |
< 1 pA (DC Amperometry) 10 pC (Integrated Amperometry) |
Cell Drive Potential Settings | -2.00 to 2.00 V in 0.001 V increments |
Optional Analog Output Range |
50 pC to 200 μC (Integrated Amperometry) 5 pA to 74 μA (DC Amperometry) |
Cell Working Electrode |
Disposable gold, silver, or platinum Non-disposable platinum, gold, silver, or glassy carbon |
Cell Counter Electrode |
Titanium |
Cell Reference Electrode | pH-Ag/AgCl combination |
Wetted Materials |
PEEK, titanium, Kel-F, polyetherimide, EPR, glass, high density polyethylene (HDPE), ULTEM, Teflon working electrode materials |
Cell Volume at Working Electrode | < 0.5 µL |
Cell Maximum Operating Pressure | 0.7 MPa (100 psi) |
Thermal Compartment | |
Temperature Control Range | 5 to 85 °C in 0.1 °C increments (41 to 185 °F in 0.18 °F increments); thermo-electric control |
Temperature Accuracy | ±0.5 °C (0.9 °F) |
Temperature Stability | ±0.1 °C (0.18 °F) |
Temperature Precision | ±0.1 °C (0.18 °F) |
Column Capacity | Up to 3 columns; maximum length of 30 cm (11.8 in) |
Heat-up Time | < 20 min from 20 to 50 °C (68 to 122 °F) |
Cooldown Time | < 20 min from 50 to 20 °C (122 to 68 °F) |
Control | Provided by Chromeleon or Chromeleon Xpress software; the TC and the host computer are connected through USB (Universal Serial Bus) |
I/O Interfaces | 2 digital inputs, 2 programmable relay outputs |
Injection Valve |
Electrically-activated Rheodyne TitanHP valve: 2-position, 6-port or 2-position, 10-port (up to two valves can be installed) |
Safety Features |
Humidity sensor and gas sensor Temperature control and temperature sensors |