The Agilent 1260 Inifnity Series G1315C Diode Array Detector VL+ is designed for highest optical performance, GLP compliance and easy maintenance.
S/N: DEAA200671
Features:
- 80 Hz data acquisition rate for fast LC applications
- data recovery (DRC) feature provides data-never-lost insurance
- RFID tags for all flow cells and UV-lamps provides traceable information about these assemblies
- long-life deuterium with RFID tag and tungsten lamps for highest intensity and low detection limit
- no loss in sensitivity for up to eight wavelengths simultaneous
- easy front access to lamps and flow cell for fast replacement
- built-in holmium oxide filter for fast wavelength accuracy verification
- built-in temperature control for improved baseline stability
- additional diagnostic signals for temperature and lamp voltage monitoring
Specifications:
Type | Specifications |
---|---|
Detection type | 1024-element photodiode array |
Light source | Deuterium and tungsten lamps |
Data rate | up to 80 Hz |
Wavelength range | 190 – 950 nm |
Short term noise (ASTM) Single and Multi-Wavelength | < ± 0.7·10-5 AU at 254 and 750 nm |
Drift | < 0.9·10-3 AU/h at 254 nm |
Linear absorbance range | > 2 AU (5 %) at 265 nm |
Wavelength accuracy | ± 1 nm |
Wavelength bunching | 1 – 400 nmProgrammable in steps of 1 nm |
Slit width | 1, 2, 4 , 8, 16 nm |
Diode width | < 1 nm |
Flow cells | Standard: 13 μL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum Standard bio-inert: 13 μL volume, 10 mm cell path length and 120 bar (1740 psi) pressure maximum Semi-micro: 5 μL volume, 6 mm cell path length and 120 bar (1740 psi) pressure maximum Micro: 2 μL volume, 3 mm cell path length, 120 bar (1740 psi) pressure maximum Semi-nano: 500 nL volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum Nano: 80 nL volume, 6 mm cell path length and 50 bar (725 psi) pressure maximum High pressure: 1.7 μL volume, 6 mm cell path length and 400 bar (5800 psi) pressure maximum Prep SST: 3 mm cell path length and 120 bar (1740 psi) pressure maximum Prep Quartz:0.3 mm cell path length and 20 bar (290 psi) pressure maximum Prep Quartz: 0.06 mm cell path length and 20 bar (290 psi) pressure maximum |
Time programmable | Wavelength, polarity, peak width, lamp bandwidth, autobalance, wavelength range, threshold, spectra storage mode |
Spectral tools | Data analysis software for spectra evaluation, including spectral libraries and peak purity functions |
Control and data evaluation | Agilent ChemStation for LC (32-bit) |
Local Control | Agilent Instant Pilot (G4208A) |
Analog outputs | Recorder/integrator: 100 mV or 1 V output range 0.001 – 2 AU, two outputs |
Communications | Controller-area network (CAN), RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN |
Safety and maintenance | Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP features | RFID for electronics records of flow cell and UV lamp conditions (path length, volume, product number, serial number, test passed, usage) Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-setable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter. |
Housing | All materials recyclable. |
Others | Electronic temperature control (ETC) for the complete optical unit |