This HP / Agilent 1200 Series HPLC system comes with the followings:
- G1322A Degasser
- G1310A Isocratic Pump
- G1329A Autosampler or Manual Injector
- G1316A TCC
- G1314B Variable Wavelength Detector
- Solvent Tray
- PC with Suitable software and all essential cables required for full operation
This Agilent 1200 Series HPLC system is in a great shape. It has been tested at SpectraLab Scientific.
A 90 day warranty is included.
Performance Specifications
G1310A Iso Pump | |
---|---|
Hydraulic system | Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve |
Settable flow range | 0.001 – 10 ml/min, in 0.001 ml/min increments |
Flow range | 0.2 – 10.0 ml/min |
Recommended pH range | 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel. |
Operating voltage | 230V |
Hydraulic system | Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve |
Settable flow range | 0.001 – 10 ml/min, in 0.001 ml/min increments |
G1329A Autosampler | |
---|---|
Type | Specification |
GLP features | Early maintenance feedback (EMF), electronic records of maintenance and errors |
Communications | Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output |
Safety features | Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display |
Injection range | 0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification required) |
Replicate injections | 1 – 99 from one vial |
Precision | Typically < 0.5 % RSD of peak areas from 5 – 100 µl, Typically < 1 % RSD of peak areas from 1 – 5 µl |
Minimum sample volume | 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial |
Carryover | Typically < 0.1 %, < 0.05 % with external needle cleaning |
Sample viscosity range | 0.2 – 50 cp |
Replicate injections per vial | 1 – 99 |
Sample capacity | 100 × 2-ml vials in 1 tray 40 × 2-ml vials in ½ tray 15 × 6-ml vials in ½ tray (Agilent vials only) |
Injection cycle time | Typically 50 s depending on draw speed and injection volume |
G1316A TCC | |
---|---|
Type | Specification |
Temperature range | 10 degrees below ambient to 80 °C up to 80 °C: flow rates up to 5 ml/min |
Temperature stability | ± 0.15 °C |
Temperature accuracy | ± 0.8 °C ± 0.5 °C (with calibration) |
Column capacity | Three 30 cm |
Warm-up/cool-down time | 5 minutes from ambient to 40 °C 10 minutes from 40 – 20 °C |
Dead volume | 3 µl left heat exchanger 6 µl right heat exchanger |
Communications | Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series module |
Safety and maintenance | Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP features | Column-identification module for GLP documentation of column type |
Housing | All materials recyclable |
G1314B VWD | |
---|---|
Type |
Specification |
Detection type |
Double-beam photometer |
Light source |
Deuterium lamp |
Noise |
± 0.75 x 10 -5 AU, at 254 nm |
Drift |
3 x 10-4AU/hr, at 254 nm |
Linearity |
>2 AU upper limit |
Wavelength range |
190-600 nm |
Wavelength accuracy |
± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter |
Wavelength bandwidth |
6.5 nm typical over whole wavelength range |
Maximum data rate |
13 Hz |
Flow cells |
Standard: 14-µL volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum |
Communications |
Controller-area network (CAN), RS-232. APG Remote:ready, start, stop and shut-down signals, LAN optional |
Safety and maintenance |
Extensive diagnostics, error detection and display through control module and Agilent ChemStation, leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP |
Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage, display of feedback messages if preset limits are exceeded. Verification of wavelength accuracy with built-in holmium oxide filter. |
Housing |
All materials recyclable |