TSP P4000, UV 2000 HPLC System

 

  • P4000 Specifications:
  • Pump Design: Dual in-line piston, pulseless design. Micro-stepped motor control. Floating piston bayonet-mounted heads. Patented ceramic check valves.
  • Flow accuracy: ±0.5% at 1 ml/min with water, after liquid end calibration.
  • Flow precision: <0.2% RSD
  • Flow Range: 0.01 to 10 ml/min standard. Settable in 0.01 ml/min increments.
  • Composition Repeatability: 0.2% RSD
  • Gradient Linearity: ±0.5% from 10-90% composition
  • Maximum Pressure: 6000 psi, 420 bar, 42MPa with standard heads
  • Wetted Surfaces: Stainless steel or PEEK, titanium, ceramic, sapphire, Teflon, Tefzel, and polyethylene
  • Pressure Pulsation: <2% amplitude; <1% typical at 1ml/min water or methanol at >500 psi
  • Delay Volume: <0.6ml
  • Compressibility Compensation: Automatic
  • Shutdown File: Protected in non-volatile memory
  • Flow Stability Test: Pump flow diagnostic to verify proper pump performance
  • Diagnostics: Diagnostic tests to verify proper electrical and mechanical operation
  • Communications: Hardwire external events connector. Run and Stop remote inputs; Ready, Run, Timed Event and Analog Pressure outputs. SCM400 degas communication port.
  • Ambient Environment: 10-40°C, 5-95% relative humidity, noncondensing.
  • UV 2000 Detector Specifications
  • Wavelength Ranges: D2 lamp: 190 to 365 nm, W lamp: 366 to 800 nm
  • Lamp: D2 and W standard
  • Wavelength Accuracy: ± 1.0 nm
  • Wavelength Precision: <0.01 nm
  • Bandwidth: 6 nm
  • Range Selections: 3.0, 2.0, 1.0, 0.5, 0.2, 0.1, 0.05, 0.02, 0.01, 0.005, 0.002, 0.001, 0.0005 AUFS
  • Absorbance Range: 0.0005 to 3.0 AUFS
  • Absorance Linearity @ 254 nm: 3.0 AUFS
  • Analog Outputs: Outputs 1 and 2: Range-selectable over entire absorbance range
  • Communications:
    - Romote Inputs: Run, Stop, and Zero
    - Romote Output: Ready
  • AS 3000 Autosampler
  • Vial capacity:
    - 120 vials in three removable trays
    - 105 vials with tray temperature control
  • Variable-Volume:
    - Injection Precision: <0.5 % RSD @ 10 pL or greater
    - Injection Volume: 0.1 - 100 pL injection standard (250 uL syringe) up to 1000 uL injections with larger loops and syringes
  • Fixed-Loop:
    - Injection Precision: <0.5% RSD @ 10 uL or greater
    - Injection Volume: 20 uL standard (250 uL syringe) 1000 uL injections with larger loops and syringes
  • Sample Carryover:
    - <0.0 I% at 300 gL flush volume
    - 5 mL flush volumes can be set
  • Minimum Sample Volume: 1 uL can be injected from 5 uL with an end-port needle
  • Needle Height: Programmable in 0.1 mm increments
  • Method Files: Protected in non-volatile memory
  • Communications
    - Remote Inputs: Pump Ready, Inject Hold
    - Outputs Pump Stop, Autosampler Ready, Inject, Gradient Start, Four timed-event outputs
    - SpectraNETIRS-232 port
  • Ambient Environment: 10° - 40°C, 5 - 95% relative humidity
  • Dimensions: 37cm x 41cm x 51cm (HxWxD)