HP Agilent 1100, G2226A Nano HPLC System

 
HP Agilent 1100, G2226A Nano HPLC System
HP Agilent 1100, G2226A Nano HPLC System
HP Agilent 1100, G2226A Nano HPLC System
 

This Agilent 1100 System is equipped with the following:

- G2226A NanoBin Pump 

- G1389 u Well PlaceAutosampler

- G1315B DAD with nano flow cell

- G1316A Column compartment

- Suitable software, PC, LAN Connections, and all necessary cables required for full operation.

**The set is also suitable for LC/MS as well**

Agilent 1100 NanoBin Pump

Type

Specification

Hydraulic system

Two dual piston in series, with proprietary servo-controlled variable

stroke drive, floating piston, active inlet valve, solvent selection valve

and electronic flow control for flow rates from 0.1 to 1 µl/min

Settable column flow Range

0.01 – 4 µl/min

1 – 2500 µl/min (with the electronic flow control bypassed)

Recommended column flow range

0.1 – 1 µl/min

200 – 2500 µl/min (with the electronic flow sensor bypassed)

Optimum composition Range

1 to 99% or 5 µl/min per channel (primary flow), whatever is greater

Composition precision

< 0.2 % SD, at 500 nl/min (default settings),

Minimum primary flow/pump channel is 5 µl/min

Delay volume

Typically 300 nl from the electronic flow control to the pump outlet for flow rates up to 4 µl/min. For flow rates up to 4 µl/min and electronic flow control active: primary flow path 180 - 480 µl; system pressure dependent (default settings; calculated volume)Typically 180 to 480 µl (system pressure dependent) for flow rates up to 2.5 ml/min. (default settings; calculated volume)

Pressure range

20 to 400 bar (5880 psi) system pressure

Compressibility compensation

User-selectable, based on mobile phase compressibility

Recommended pH Range

1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries

Control and data Evaluation

Agilent ChemStation for LC

Analog output

For pressure monitoring, 2 mV/bar, one output

Communications

Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready,

start, stop and shut-down signals, LAN optional

Safety and maintenance

Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.

GLP features

Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.

Housing

All materials recyclable

Agilent 1100 Series G1389 U Well PlaceAutosampler

Type

Specification

Sample capacity

100 x 2 ml vials in 1 tray. Microvials (100 or 300 µl) with sleeves (reduced cooling performance with microvials)

Settable injection volume

0.01 to 8 µl with small loop capillary

0.01 to 40 µl with extended loop capillary

Precision

Typically < 0.5 % RSD from 5 to 40 µl

Typically < 1 % RSD from 1 to 5 µl

Typically < 3 % RSD from 0.2 to 1 µl

Minimum sample volume

1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in

300 µl microvials

Carryover

Typically < 0.1 % without automated needle wash

Typically < 0.05 % with external needle cleaning and 1 µl injection Volume

Sample viscosity range

0.2 - 5 cp

Recommended pH-range

1.0 - 8.5 solvent with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries

Material in contact with

Solvent

Stainless steel, sapphire, PTFE, PEEK, fused silica, Vespel

GLP features

Early maintenance feedback (EMF),electronic records of maintenance and errors

Communications

Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output

Safety features

Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display

Housing

All material recyclable

Agilent 1100 Series G1315B DAD with nano flow cell

Type

Specification

Detection type

1024-element photodiode array

Light source

Deuterium and tungsten lamps

Wavelength range

190 – 950 nm

Short term noise (ASTM)

Single and Multi-Wavelength

± 1 × 10-5AU at 254 and 750 nm

Drift

2 × 10-3AU/hr at 254 nm

Linear absorbance range

> 2 AU (upper limit)

Wavelength accuracy

± 1 nm

Wavelength bunching

1 – 400 nm

Slit width

1, 2, 4 , 8, 16 nm

Diode width

< 1 nm

Flow cells

Standard: 13 µl volume, 10 mm cell path length

and 120 bar (1760 psi) pressure maximum

Semi-Micro: 5 µl volume, 6 mm cell path length

and 120 bar (1760 psi) pressure maximum

Micro: 2 µl volume, 3 mm cell path length and

120 bar (1760 psi) pressure maximum

High pressure: 1.7 µl volume, 6 mm cell path

length and 400 bar (5880 psi) pressure maximum

80 nano: 0.08 µl volume, 10 mm cell path length

and 50 bar (725 psi) pressure maximum

500 nano: 0.5 µl volume, 10 mm cell path length

and 50 bar (725 psi) pressure maximum

Control and data evaluation

Agilent ChemStation for LC

Analog outputs

Recorder/integrator: 100 mV or 1 V, output range

0.001 – 2 AU, two outputs

Communications

Controller-area network (CAN), GPIB, RS-232C,

APG Remote: ready, start, stop and shut-down

signals, LAN optional

Safety and maintenance

Extensive diagnostics, error detection and display

(through control module and ChemStation), leak

detection, safe leak handling, leak output signal

for shutdown of pumping system. Low voltages in

major maintenance areas.

GLP features

Early maintenance feedback (EMF) for continuous

tracking of instrument usage in terms of lamp burn

time with user-settable limits and feedback

messages. Electronic records of maintenance and

errors. Verification of wavelength accuracy with

built-in holmium oxide filter.

Housing

All materials recyclable


Agilent 1100 Series Column compartment G2226A

Type

Specification

Temperature range

10 degrees below ambient to 80 °C

up to 80 °C: flow rates up to 5 ml/min

Temperature stability

± 0.15 °C

Temperature accuracy

± 0.8 °C

± 0.5 °C (with calibration)

Column capacity

Three 30 cm

Warm-up/cool-down time

5 minutes from ambient to 40 °C

10 minutes from 40 – 20 °C

Dead volume

 

3 µl left heat exchanger

6 µl right heat exchanger

Communications

Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series module

Safety and maintenance

Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.

GLP features

Column-identification module for GLP

documentation of column type

Housing

All materials recyclable


The equipment has been tested and is in FULL working order.

Please ask us about different WARRANTY options for this excellent system.

We only carry QUALITY products that will satisfy your analytical and budgetary needs.

Thanks for looking and we look forward to hearing from you!

 
 
  Price: New arrival
  INQUIRE/OFFER
 
  Please Call Us at Toll Free Number:
1-866-777-3688 Tel: 905-946-8066
 
Contact by email at:
info@spectralabsci.com


 

The one stop shop for all your analytical laboratory needs! Your source for

PRE-OWEND Spectralab Scientific Incorporation CERTIFIED Equipment.

We buy your laboratory or surplus analytical equipment:

Contact buy@spectralabsci.com

Trade-in “service or analytical equipment”:

available via info@spectralabsci.com

*
  Feature Products:
   

Copyright 2014 SpectraLab Scientific Inc. All right reserved. Please contact us by email at: info@spectralabsci.com

Being supported and modified by Spectralab, contact by email at:info@spectralabsci.com