header

Pre-owned Equipment

Parts Depot

 

HP 1090 Series II HPLC

 
HP 1090 Series II HPLC
  This refurbished HP 1090 Series II HPLC is in great condition. It has been tested at SpectraLab Scientific.

Specifications
Solvent delivery system
Configuration 

Isocratic, PV5 ternary or quaternary, DR5 binary or ternary

Ranges
Pressure: 0-400 bar (0-5880 psi).
Flow: 0-5000 µl/min, in 1µl/minsteps
Flow Accuracy: +2% of setpoint or +1 µl/min
Whichever is greater, independent of back pressure and solvents, excluding volume contraction effects
Precision: <0.3% RSD, based on retention time

Composition

Precision PV5: +0.25% absolute, peak to peak, water/acetonitrile, 500µl/min, 2500 µl/min
Precision PV5: +0.15% absolute, peak to peak, water/acetonitrile, 50µl/min, 2500 µl/min

Delay Volume
PV5: 1750-2000 µl maximum, dependent on back pressure
DR5: 300-500 µl maximum, dependent on back pressure
Heated Compartment
Solvent and samples are preheated in low-volume (2µl) heat exchanger with optional cooling for sub-ambient operation

Settable Temperature range: 0-100°C in 0.1°C steps.
Controlled temperature range: 20 °C above ambient to 100°C
Temperature stability: +0.5 °C
Injection system
Maximum pressure: 400 bar (5880 psi)
Manual Injector
Rheodyne valves 7125 or 7413, with loops from 0.5 µl to 100 µl

Auto-injector
Injection volume: -25 µl (standard), or 0.1-250 µl (optional), in 0.1 µl steps
Precision
<1% (typically 0.6%) RSD from 2-25 µl (25 µl syringe);
<1% (typically 0.6%) RSD from 10-250 µl (250 µl syringe)
Sample vials: 0 ml standard, 300 disposable micovial, 100 µl microvial
Minimum Sample volume: 40 µl (2 ml standard vial), 20 µl (300 µl disposable microvial), 5 µl (100 µl microvial)
Auto-sampler: 10 removable magazines with 10 vials each (standard or microvials), with random access time < 10 seconds from any position.
Filter-photometric detector
Filters
Interference: 254 nm standard, 210,230,269,280,340,430 and 540 nm optional.
Bandwidth: 10 nm typically.

Signal Characteristics

Noise: 5x 10 E-5 AU
Drift: <1 x 10 E-3 AU/hour
Signal Ranges
Linear absorbance range: -0.1 to 1.5 AU
Response time: 100,400 and 800(10-90%)
Flow Cell
Stainless steel cell with 4.5 µl volume, 6 mm path length and maximum pressure of 100 bar (1470 psi).
Diode-array detector

Up to eight signals with definable sample and reference wavelength and bandwidth

Signal Characteristics
Noise: +3.5 x 10 E-5 AU
Drift: <2 x 10 E-3 AU/hour

Signal ranges
Wavelength range: 190 – 600 nm, in steps of 1 nm
Bandwidth range: 4-400 nm, in steps of 1 nm
Linear absorbance range: -0.1 to 1.5AU

Spectral ranges 
Wavelength range: 190 – 600 nm
Linear absorbance range: -0.1 to 1.5AU
Scan Time: 10 msec from 190-600 nm

Flow cells
Standard cell: 8 µl, 6 mm, max pressure 120 bar
High sensitivity cell: 13 µl, 10 mm,max pressure 120 bar
Slits: 2,4, and 8 nm selectable

A 90 day warranty is included.

We are seasoned professionals in this area and we would be extremely happy to have you speak with one of our experts here at SpectraLab.

Thanks for looking and we look forward to hearing from you!

Multiple available
 
 
  Price: $5,800 USD
  INQUIRE/OFFER
 
  We will match prices with our competitors
  Please Call Us at Toll Free Number:
1-866-777-3688 Tel: 905-946-8066
 
Contact by email at:
info@spectralabsci.com


 

The one stop shop for all your analytical laboratory needs! Your source for

PRE-OWNED Spectralab Scientific Incorporation CERTIFIED Equipment.

We buy your laboratory or surplus analytical equipment:

Contact buy@spectralabsci.com

Trade-in “service or analytical equipment”:

available via info@spectralabsci.com

*
  Feature Products:
   

Copyright 2014 SpectraLab Scientific Inc. All right reserved. Please contact us by email at: info@spectralabsci.com

Being supported and modified by Spectralab, contact by email at:info@spectralabsci.com