header

Pre-owned Equipment

Parts Depot

 

Dionex Ics-3000 Ion Chromatography System

  Dionex-04-0690
 
Dionex Ics-3000 Ion Chromatography System
Dionex Ics-3000 Ion Chromatography System
Dionex Ics-3000 Ion Chromatography System
Dionex Ics-3000 Ion Chromatography System
  Features
The ICS-3000 Ion Chromatography System provides an impressive combination of increased productivity, expanded capabilities, and improved performance. Innovations in all modules provide up to an order of magnitude improvement in performance—the foundation of the system. Modular versatility, functional integration, and superior performance culminate in the most advanced ion chromatography system on the market.
  • Modular design allows versatility in configuring a wide variety ofapplications
  • Performance improvements up to an order of magnitude in flow rateaccuracy, eluent generator electronicsstability, and conductivity celltemperature control increase retention time reproducibility, baselinestability, and sensitivity
  • New hydroxide and  carbonate Reagent-Free Ion Chromatography(RFIC) consumables offer the greatest flexibility of any RFICsystem  
  • Dual-system capability (within the same footprint)  maximizesthroughput
  • Integrated DC Detector/Chromatography module with precisely controlledtemperature zones maintains baseline stability and increases applicationflexibility
  • AM Automation Manager simplifies and automates complex applicationsincluding sample preparation, preconcentration, matrix elimination andpost column reagent addition
  • New innovative ED Electrochemical Detector capabilities improve andexpand applications: multiwaveforms in a single run; post-run 3-D dataprocessing; new cell design
  • Innovative touchscreen TabletStation, mounted on a movable arm, unifies and simplifies system control and operation
Specifications

Feature

Isocratic Pump

Gradient Pump

Pump

Dual-piston (in series), variable speed, 80 μL per revolution

Dual-piston (in series), variable speed, 80 μL per revolution

Flow Rate Range

0.001 to 10.0 mL/min in increments of 0.001 mL/min

0.001 to 10.0 mL/min in increments of 0.001 mL/min

Flow Rate Accuracy

and Reproducibility

±0.1% at 1.0 mL/min (typical)

±0.1% at 1.0 mL/min (typical)

Operating Pressure

0.1 to 35 MPa  (15 to 5000 psi)

0.1 to 35 MPa (15 to 5000 psi)

Pressure Ripple

1% (typical)

1% (typical)

Gradient Proportioning Accuracy and Reproducibility

Not applicable

±0.5% at 2.0 mL/min (typical)

Number of Eluents

One

Four

Gradient Mixer Delay Volume

Not applicable

GM-3: <500 μL, 3 to 9 mm ID columns

GM-4: <290 μL, 2 mm ID columns

High Pressure Limit

0 to 35 MPa (0 to 5000 psi) in increments of 0.1 MPa (14 psi); trips instantaneously

0 to 35 MPa (0 to 5000 psi) in increments of 0.1 MPa (14 psi); trips instantaneously

Low Pressure Limit

0 to 34 MPa (0 to 4900 psi) in increments of 0.1 MPa (14 psi)

0 to 34 MPa (0 to 4900 psi) in increments of 0.1 MPa (14 psi)

Vacuum Degassing

Module

Built-in single-channel degas chamber (with degassing membrances) with internal volume of 670 µL and dual-stage diaphragm vacuum pump

Built-in four-channel degas chamber (with degassing membranes) with internal volume of 670 μL per channel and dual-stage diaphragm vacuum pump


Eluent Generator  

 

Operating

Temperature

4 to 40 °C (40 to 104 °F)

Operating

Humidity

5% to 95% relative humidity, noncondensing

Operating Pressure

Minimum: 14 MPa (2000 psi)

Maximum: 21 MPa (3000 psi)

Dimensions

Height: 40.6 cm (16 in)

Width: 22 cm (8.75 in)

Depth: 55.9 cm (22 in)

Minimum required clearance behind the EG: 5 cm (2 in)

Weight

18 kg (40 lb)


Conductivity Detector

 

Electronics

Microprocessor-controlled digital signal processing

Detection Types

Single- or dual-conductivity detection. Dual-detection can be controlled either simultaneously or independently

Cell Drive

8 kHz square wave

Linearity

1% at 1000 µS

Resolution

0.10 nS

Signal Sampling Rate

Maximum of 100 Hz

Electronic Noise, Dry

S/N ratio = 200,000:1 (Example: 1000 µS:5 nS)

Electronic Noise, Wet

At 23 µS, noise <0.2 nS

At 1 µS, noise <0.1 nS

Filter

Rise times from 0 to 10 s

Temperature Compensation

Factory set at 1.7% per °C; programmable from 0.0 to 3.0% per °C

Cell Body

PEEK

Cell Electrodes

Passivated 316 stainless steel

Active Volume of Cell

< 1.0 µL

Cell Operating Temperature

5 ºC above the DC detector compartment temperature; maximum of 60 ºC

Cell Maximum Operating Pressure

3 MPa (500 psi)

Signal Gain Ranges

0 to 180 µS, 0 to 1000 µS, and 0 to 15,000 µS

Optional Analog Output Full-Scale Ranges

Three separate ranges from 0 to 15,000 µS

 

Electrochemical Detector

 

Electronics

Microprocessor-controlled digital signal processing

Detection Types

Single- or dual-electrochemical detection. Dual-detection can be controlled either simultaneously or independently.

Noise

< 1 pA (DC Amperometry)

10 pC (Integrated Amperometry)

Cell Drive Potential Settings

-2.00 to 2.00 V in 0.001 V increments

Optional Analog Output Range

50 pC to 200 μC (Integrated Amperometry)
5 pA to 74 μA (DC Amperometry)

Cell Working Electrode

Disposable gold, silver, or platinum

Non-disposable platinum, gold, silver, or glassy carbon

Cell Counter

Electrode

Titanium

Cell Reference Electrode

pH-Ag/AgCl combination

Wetted Materials

PEEK, titanium, Kel-F, polyetherimide, EPR, glass, high density

polyethylene (HDPE), ULTEM, Teflon working electrode

materials

Cell Volume at Working Electrode

< 0.5 µL

Cell Maximum Operating Pressure

0.7 MPa (100 psi)


Thermal Compartment

 

Temperature Control Range

5 to 85 °C in 0.1 °C increments (41 to 185 °F in 0.18 °F increments); thermo-electric control

Temperature Accuracy

±0.5 °C (0.9 °F)

Temperature Stability

±0.1 °C (0.18 °F)

Temperature Precision

±0.1 °C (0.18 °F)

Column Capacity

Up to 3 columns; maximum length of 30 cm (11.8 in)

Heat-up Time

< 20 min from 20 to 50 °C (68 to 122 °F)

Cooldown Time

< 20 min from 50 to 20 °C (122 to 68 °F)

Control

Provided by Chromeleon or Chromeleon Xpress software; the TC and the host computer are connected through USB (Universal Serial Bus)

I/O Interfaces

2 digital inputs, 2 programmable relay outputs

Injection Valve

Electrically-activated Rheodyne TitanHP valve: 2-position, 6-port

or 2-position, 10-port (up to two valves can be installed)

Safety Features

Humidity sensor and gas sensor

Temperature control and temperature sensors

This Dionex Ics-3000 Ion Chromatography System includes:
  • Dionex ICS-3000 Dual Pump (DP)
  • Dionex ICS-3000 Eluent Generator(EG)
  • Dionex ICS-3000 Detector/Chromatography Module
  • Dionex AS-40 Autosampler
This refurbished Dionex Ics-3000 Ion Chromatography System is in good condition. 

We encourage you to contact us to speak with one of our expert and professional team members.

Thanks for looking and we look forward to hearing from you!

 
 
  Price: In Stock Call for Quote
  INQUIRE/OFFER
 
  We will match prices with our competitors
  Please Call Us at Toll Free Number:
1-866-777-3688 Tel: 905-946-8066
 
Contact by email at:
info@spectralabsci.com


 

The one stop shop for all your analytical laboratory needs! Your source for

PRE-OWNED Spectralab Scientific Incorporation CERTIFIED Equipment.

We buy your laboratory or surplus analytical equipment:

Contact buy@spectralabsci.com

Trade-in “service or analytical equipment”:

available via info@spectralabsci.com

*
  Feature Products:
   

Copyright 2014 SpectraLab Scientific Inc. All right reserved. Please contact us by email at: info@spectralabsci.com

Being supported and modified by Spectralab, contact by email at:info@spectralabsci.com