Specification

 

Optical system

Ratio photometry; intensity of transmitted beam is monitored.

Light source

Xe lamp (150 W)

Hg lamp (for checking wavelength)

Measuring wavelength range Excitation wavelength

200 to 850 nm/Zero order

Measuring wavelength range emission wavelength

250 to 900 nm/Zero order

Photomultiplier must be changed at emission wavelength greater than 731 nm

Spectral bandwidth excitation side

15 nm

Spectral bandwidth emission side

15 nm, 30 nm (variable)

* With this instrument, spectrum bandwidth is defined by half-value width. Therefore, in order to

separate a spectrum completely, a wavelength interval of 30 nm or more is required

Wavelength setting

By communication (E-line) or keyboard

Wavelength accuracy

±3 nm

Wavelength repeatability

±0.5 nm

Recorder output (option)

10 mV full-scale; full scale range 1 to 1000 settable in increments of 1

Processor output (option)

1 V full-scale  -40 to 1000 mV

Response

Changeable in 7 steps corresponding to time constants of 0.05/0.1/0.5/1.0/2.0/4.0/8.0 seconds

Sensitivity

a. With emission-side spectral bandwidth set at 15 nm

S/N ratio for Raman peak of water

700 or more (Baseline method)

S/N ratio for Raman peak of water

525 or more (Tangent method)

b. With emission-side spectral bandwidth set at 30 nm

S/N ratio for Raman peak of water

900 or more (Baseline method)

Wavelength: 350 nm, Time constant: 2.0 s

Auto Zero range

0 to 1000

Offset range

0 to 1000 (settable in steps of 1)

Time program

Number of programs 9

Settable time Up to 600 minutes increments of 0.1 minute

Number of steps storable 100 steps for a total of 9 files

Programmable parameters Measurement wavelength

(Ex and Em)

Baseline processing

PMT gain

External Output terminals

Analog output for processor 1 V full scale

Analog output for recorder 10 mV full scale

Flow cell capacity

Standard cell 12 μL (irradiated capacity)

Flow cell withstand pressure

1.0 MPa

Operating temperature range

4 to 35 °C (non-condensing)

Operating humidity range

25 to 85% RH (non-condensing)


This refurbished Perkin Elmer 200 Series Fluorescence Detector (FLD) is in great condition. It has been tested at SpectraLab Scientific.

A 90 day warranty is included.

We are seasoned professionals in this area and we would be happy to have you speak with one of our experts here at SpectraLab.

Thanks for looking and we look forward to hearing from you!

 
 
  Price: $4,350 USD
  INQUIRE/OFFER
 
  Please Call Us at Toll Free Number:
1-866-777-3688 Tel: 905-946-8066
 
Contact by email at:
info@spectralabsci.com


 

The one stop shop for all your analytical laboratory needs! Your source for

PRE-OWEND Spectralab Scientific Incorporation CERTIFIED Equipment.

We buy your laboratory or surplus analytical equipment:

Contact buy@spectralabsci.com

Trade-in “service or analytical equipment”:

available via info@spectralabsci.com

*
  Feature Products:
   

Copyright 2014 SpectraLab Scientific Inc. All right reserved. Please contact us by email at: info@spectralabsci.com

Being supported and modified by Spectralab, contact by email at:info@spectralabsci.com