Waters Alliance e2695 HPLC system with Waters 2489 UV/Vis Detector

 
Waters Alliance e2695 HPLC system with Waters 2489 UV/Vis Detector
Waters Alliance e2695 HPLC system with Waters 2489 UV/Vis Detector
 
Solvent Management
 
Number of solvents
One to four
Solvent conditioning
Vacuum degas, two operating modes, four chambers, 500 µL internal volume per chamber
Flow rate range
0.000 to 10.000 mL/min (0.050 to 5.000 mL/min typical) in 0.001 mL/min increments
Compressibility compensation
Automatic continuous
System delay volume
< 650 µL, independent of backpressure at 1 mL/min
Plunger seal wash
Integral, active, programmable
Gradient profiles
11 gradient curves (including linear, step [2], concave [4], and convex [4])
Dry prime/ wet prime
Automatic front panel control, SystemPREP function for automatic solvent(s) purge
Flow ramping
Time (0.01 to 30.00 min in 0.01 min increments) to reach maximum flow rate
Maximum operating pressure
500 psi (345 bar)(0.010 to 3.000 mL/min) programmable upper and lower limits
Composition range
0.0% to 100.0%, in 0.1% increments
Composition accuracy
+0.5% absolute, independent of backpressure (proportioning valve pair test,[degassed methanol: methanol/proplyparaben, 2.0 mL/min, 254nm])
Composition precision
<0.15% RSD or <0.02 min SD, six replicates, based on retention time or volumetric measures (0.200 to 5.000 mL/min),isocratic premix
Flow accuracy
+1% or 10 µL/min, which is greater, 0.200 to 5.000 mL/min,

Sample management
 
Number of samples vials
120 vials, configured in five carousels of 24 vials each
Number of sample injections
1 to 99 injections per sample vial
Sample delivery precision
Typically <0.5% RSD, 5 to 80 µL (degassed methanol: water 60:40 dial-a-mix, 1 mL/min, six replicates, phenone mix, 254 nm)
Sample  carryover
<0.01% for caffeine, under specified conditions
Injection needle wash
Integral, active, programmable
Injection accuracy
+1µL (+2%)(50µL, N-6), sample: 100% degassed water, analytical solvent: 100% degassed methanol
Standard sample vial
2 mL
Advanced operations
Priority samples, auto additions, auto standards
Injection volume range
0.1 to 100 µL, standard; 0.1 to 2000 µL, with optional sample loop
Injector linearity
>0.999 coefficient of deviation (1.000 to 100.000 µL)
Minimum sample required
10 µL, using low volume inserts
Sample temperature control (optional)
4 to 40°C, programmable in 1°C increments
Column heater (optional)
20 to 65 °C, in 1 °C increments (5°C above ambient)
Column heater/cooler(optional)
Ambient minus 15°C to 4°C (whichever is greatest) up to 65°C, in 1°C increments

Waters 2489 UV/Vis detector
Condition
Specification
Wavelength range
190 to 700 nm
Bandwidth
<5 nm
Wavelength accuracy
+1.0 nm
Wavelength repeatability
+0.1 nm
Single λ dry noise
<5 µAU
(at 230 nm, 1 –second digital filter, 30-second segments, 10-Hz data rate, analytical cell)
Wet noise
<8 µAU
(at 230 nm, 1-second digital filter 30-second segments, 10-Hz data rate, analytical cell)
Dual channel noise (dry)
<35 µAU
(measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; dry, analytical cell)
Dual channel noise (wet)
<45 µAU
(measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; 1 ml/min, flow of acetonitrile, analytical cell)
Linearity
<5% at 2.5 AU, propylparaben at 257 nm
Drift
1.0 x 10-4 AU/hr. max (∆T = +2°C/hr.)
Thermal drift
1.0 x 10-4 AU/°C max (∆T = +2°C/hr.)
Sensitivity setting range
0.0001 to 4.0000 AUFS
Filter setting range
Single-wavelength: 0.1 to 5.0 seconds
Dual-wavelength: 1 to 50 seconds
Time-constant
To 5.0-second Hamming filter
Digital data rates
1,2,5,10,20,40,80 Hz (single channel)
1,2 Hz (dual channel)
Analog output data rates (single λ mode)
10,20,40,80 Hz (channel A)
10 Hz only (channel B)
Lamp source
30-W High Brightness Deuterium lamp, 0.5 nm aperture, pre-aligned 2000 silicon photodiodes (matched pair)
Second-order filter
Automatic for wavelengths > 370 nm
Wavelength calibration filter
Erbium filter, used at startup or on demand
Flow cell
TaperSlit flow cell design
Nitrogen purge
Purge fitting present on optics bench
Path length
10 mm (standard analytical)
Cell volume
10 µL (standard analytical)
Pressure limit
6895 kPa (69 bar,1000 psi)
Materials
316 stainless steel, fused silica, Tygon
Operating temperature
4 to 40 °C (39 to 104 °F)
Operating humidity
20% to <95%, noncondensing
Shipping and storage
-30 to +60 °C
Shipping and storage humidity
0% to <95% noncondensing

This Waters Alliance e2695 HPLC system comes with Waters 2489 UV/Vis Detector. They are in great condition and have been tested at SpectraLab Scientific.

A 90 days warranty is included.

We have special expertise on analytical equipment. We encourage you to contact us to speak with one of our expert and professional team members.

Thanks for looking and we look forward to hearing from you!
 
 
  Price: In Stock Call for Quote
  INQUIRE/OFFER
 
  We will match prices with our competitors
  Please Call Us at Toll Free Number:
1-866-777-3688 Tel: 905-946-8066
 
Contact by email at:
info@spectralabsci.com


 

The one stop shop for all your analytical laboratory needs! Your source for

PRE-OWNED Spectralab Scientific Incorporation CERTIFIED Equipment.

We buy your laboratory or surplus analytical equipment:

Contact buy@spectralabsci.com

Trade-in “service or analytical equipment”:

available via info@spectralabsci.com

*
  Feature Products:
   

Copyright 2014 SpectraLab Scientific Inc. All right reserved. Please contact us by email at: info@spectralabsci.com

Being supported and modified by Spectralab, contact by email at:info@spectralabsci.com