Agilent 1200 Series Nano HPLC system with G1315B Detector

 
Agilent 1200 Series Nano HPLC system with G1315B Detector
Agilent 1200 Series Nano HPLC system with G1315B Detector
 
This HP/Agilent 1200 Series Nano HPLC system has just been moved from a working lab. It comes with the followings:
Performance Specification Agilent 1200 Series Nano Pump

Type

Specification

Hydraulic system

Two dual piston in series, with proprietary servo-controlled variable

stroke drive, floating piston, active inlet valve, solvent selection valve

and electronic flow control for flow rates from 0.1 to 1 µl/min

Settable column flow  range

 

 

0.01 – 4 µl/min

1 – 2500 µl/min (with the electronic flow control bypassed)

Recommended column  flow range

 

 

0.1 – 1 µl/min

200 – 2500 µl/min (with the electronic flow sensor bypassed)

Optimum composition range

 

1 to 99% or 5 µl/min per channel (primary flow), whatever is greater

Composition precision

< 0.2 % SD, at 500 nl/min (default settings),

Minimum primary flow/pump channel is 5 µl/min

Delay volume

Typically 300 nl from the electronic flow control to the pump outlet for flow rates up to 4 µl/min. For flow rates up to 4 µl/min and electronic flow control active: primary flow path 180 - 480 µl; system pressure dependent (default settings; calculated volume)Typically 180 to 480 µl (system pressure dependent) for flow rates up to 2.5 ml/min. (default settings; calculated volume)

Pressure range

20 to 400 bar (5880 psi) system pressure

Compressibility compensation

 

User-selectable, based on mobile phase compressibility

Recommended pH range

1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries.

Control and data evaluation

Agilent ChemStation for LC

Analog output  Communications

For pressure monitoring, 2 mV/bar, one output

Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready,

start, stop and shut-down signals, LAN optional

Safety and maintenance

Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.

GLP features

Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors.

Housing

All materials recyclable.








Performance Specification Agilent 1200 Series Micro Degasser

Type

Specification

Maximum flow

5 ml/min per channel

Number of channels

4

Internal volume

Typically 1 ml per channel

pH range

1-14

RS232 output

For diagnosis purpose

Material in contact with Solvents

PTFE, FEP, PEEK


Agilent 1200 series G1377A Micro WPS

Type

Specification

GLP features

Early maintenance feedback (EMF), electronic records of maintenance and errors

Communications

Communications Controller-area network (CAN). RS232C, APG-remote standard, optional four external contact closures and BCD vial number output

Safety features

Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display

Injection range

0.01– 8 µl in 0.01 µl increments with the small loop capillary 0.01–40 µl in 0.01 µl increments with the extended loop capillary

Precision

Typically < 0.5% RSD of peak areas from 5 – 40 µl, Typically < 1% RSD from 1 – 5 µl Typically < 3% RSD from 0.2 – 1 µl

Pressure range

400 bar (5880 psi)

Sample viscosity range

0.2 – 5 cp

Sample capacity

2 × well-plates (MTP) + 10 × 2 ml vials

108 x 2-mL vials in 2 x 54 vial plate plus 10 additional 2 mL vials

30 x 6-mL vials in 2 x 15 vial plate plus 10 additional 2 mL vials

54 Eppendorf tubes (0.5/1.5/2.0 mL) in 2 x 27 Eppendorf tube plate

Injection cycle time

Typically < 30 s using following standard conditions: Default draw

speed: 4 µl/min Default eject speed: 10 µl/min Injection volume:

0.1 µl

Carry-over

Typically < 0.05% using the following conditions: Column:

150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase:

Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection

volume: 1 µl caffeine (=25 ng caffeine), 1 µl water to test carry over

Outside wash of needle before injection: 20 sec with water using flush port


Agilent 1200 series G1316A TCC

Type

Specification

Temperature range

10 degrees below ambient to 80 °C

up to 80 °C: flow rates up to 5 ml/min

Temperature stability

± 0.15 °C

Temperature accuracy

± 0.8 °C

± 0.5 °C (with calibration)

Column capacity

Three 30 cm

Warm-up/cool-down time

5 minutes from ambient to 40 °C

10 minutes from 40 – 20 °C

Dead volume

 

3 µl left heat exchanger

6 µl right heat exchanger

Communications

Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series module

Safety and maintenance

Extensive diagnostics, error detection and display (through control module and Agilent Chem Station), leak detection, safe leak handling, leak output signal for shut down of pumping system. Low voltages in major maintenance areas.

GLP features

Column-identification module for GLP

documentation of column type

Housing

All materials recyclable


Agilent 1200 series G1315B DAD

Wavelength range

190-950 nm

Light source

Deuterium and tungsten lamps

Detection type

1024 - element photo diode array

Short term noise (ASTM) single & mult-wavelength

± 1° x 10-5 AU at 254 and 750 nm

Drift

2° x 10-3 AU / hr at 254 nm

Linear absorbance range

> 2 AU (upper limit)

Wavelength accuracy

± 1 nm

Wavelength bunching

1 - 400 nm

Diode width

< 1 nm

Flow cells

Standard: 13µl volume 10 mm cell path length and 120 bar (1760 psi) pressure maximum
Semi-Micro: 5µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
Micro: 2µl volume, 3 mm cell path length and 120 bar (1760 psi) pressure maximum
High Pressure: 1.7µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure max.
80 nano: 0.08µl volume, 100 mm cell path length and 50 bar (725 psi) pressure max.
500 nano: 0.5µl volume, 10 mm cell path length and 50 bar (725 psi) pressure max.

Analog outputs

Recorder / integrator: 10 mV or 1 V, output range 
0.001 - 2 AU, two outputs

Control and data evaluation

Agilent Chem station for LC

Slit width

1, 2, 4, 8, 16 nm

Communication types

CAN, GBIP, RS-232C, APG, Remote: ready, start, stop and shut down

Wavelength range

190-950 nm

Light source

Deuterium and tungsten lamps

Detection type

1024 - element photo diode array

Short term noise (ASTM) single & mult-wavelength

± 1° x 10-5 AU at 254 and 750 nm

Drift

2° x 10-3 AU / hr at 254 nm

Linear absorbance range

> 2 AU (upper limit)



























This Agilent 1200 Series Na-no HPLC system with G1315B Detector is in great condition. It has been tested at SpectraLab Scientific.   
 

A 90 day warranty is included.


We are professionals. We encourage you to contact us to speak with one of our expert and professional team members. Thanks for looking and we look forward to hearing from you!

 
 
  Price: In Stock Call for Quote
  INQUIRE/OFFER
 
  Please Call Us at Toll Free Number:
1-866-777-3688 Tel: 905-946-8066
 
Contact by email at:
info@spectralabsci.com


 

The one stop shop for all your analytical laboratory needs! Your source for

PRE-OWEND Spectralab Scientific Incorporation CERTIFIED Equipment.

We buy your laboratory or surplus analytical equipment:

Contact buy@spectralabsci.com

Trade-in “service or analytical equipment”:

available via info@spectralabsci.com

*
  Feature Products:
   

Copyright 2014 SpectraLab Scientific Inc. All right reserved. Please contact us by email at: info@spectralabsci.com

Being supported and modified by Spectralab, contact by email at:info@spectralabsci.com