Waters 2487 Dual Absorbance UV/Vis Detector

 
Waters 2487 Dual Absorbance UV/Vis Detector
  General Information:

Designed to provide the highest performance in UV/Vis detection for your HPLC analyses, Waters 2487 Dual Absorbance UV/Vis Detector offers the sensitivity required for detection of minor impurities, with the linear dynamic range to simultaneously quantitate major and minor components.

With versatile and easy programmability from the front panel keypad, timesaving qualification derived from the built-in cuvette holder, the ability to view real-time chromatograms or spectral scans via the front panel LCD display, and dual wavelength performance, the detector will enhance the productivity of any chromatography laboratory.

Waters 2487 Dual Absorbance UV/Vis Detector

 

Specification

Wavelength range

190 to 700 nm

Bandwidth

<5 nm

Wavelength accuracy

+1.0 nm

Wavelength repeatability

+0.1 nm

Single λ dry noise

<5 µAU
(at 230 nm, 1 –second digital filter, 30-second segments, 10-Hz data rate, analytical cell)

Wet noise

<8 µAU
(at 230 nm, 1-second digital filter 30-second segments, 10-Hz data rate, analytical cell)

Dual channel noise (dry)

<35 µAU
(measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; dry, analytical cell)

Dual channel noise (wet)

<45 µAU
(measured at 230 nm, running at 230 to 280 nm with 2-second filter at 1-Hz data rate; 1 ml/min, flow of acetonitrile, analytical cell)

Linearity

<5% at 2.5 AU, propylparaben at 257 nm

Drift

1.0 x 10-4 AU/hr. max (∆T = +2°C/hr.)

Thermal drift

1.0 x 10-4 AU/°C max (∆T = +2°C/hr.)

Sensitivity setting range

0.0001 to 4.0000 AUFS

Filter setting range

Single-wavelength: 0.1 to 5.0 seconds
Dual-wavelength: 1 to 50 seconds

Time-constant

To 5.0-second Hamming filter

Digital data rates

1,2,5,10,20,40,80 Hz (single channel)
1,2 Hz (dual channel)

Analog output data rates (single λ mode)

10,20,40,80 Hz (channel A)
10 Hz only (channel B)

Lamp source

30-W High Brightness Deuterium lamp, 0.5 nm aperture, pre-aligned 2000 silicon photodiodes (matched pair)

Second-order filter

Automatic for wavelengths > 370 nm

Wavelength calibration filter

Erbium filter, used at startup or on demand

Flow cell

TaperSlit flow cell design

Nitrogen purge

Purge fitting present on optics bench

Path length

10 mm (standard analytical)

Cell volume

10 µL (standard analytical)

Pressure limit

6895 kPa (69 bar,1000 psi)

Materials

316 stainless steel, fused silica, Tygon

Operating temperature

4 to 40 °C (39 to 104 °F)

Operating humidity

20% to <95%, noncondensing

Shipping and storage

-30 to +60 °C

Shipping and storage humidity

0% to <95% noncondensing



This refurbished Waters 2487 Dual Absorbance UV/Vis Detector is in great condition. It has been tested at SpectraLab Scientific.

A 90 day warranty is included.

We are professionals and we would be happy to have you speak with one of our experts here at SpectraLab.

Thanks for looking and we look forward to hearing from you!

Multiple available
 
 
  Price: $4,600 USD
  INQUIRE/OFFER
 
  Please Call Us at Toll Free Number:
1-866-777-3688 Tel: 905-946-8066
 
Contact by email at:
info@spectralabsci.com


 

The one stop shop for all your analytical laboratory needs! Your source for

PRE-OWEND Spectralab Scientific Incorporation CERTIFIED Equipment.

We buy your laboratory or surplus analytical equipment: